With unequaled elegance, Kozy Heat's distinctive Model 234 has set the standard for quality and performance.

Standard Features
   130,000 Btu's
  Black, Air-Seal, Square Cast Iron Doors (2)
  73% efficient
   10" Clay Flue Adaptor
  4" Outside Air Flex Pipe
  Borofloat Safety Glass ( (2) 14½" x 17")
  Chimney Damper Control
  Combustion Air Damper Control
  Adjustable Legs (for leveling unit)
  10 Year Limited Warranty


Optional Features

  Black Upper & Lower Grills
  Brass Upper & Lower Grills
  Face Trim - Brass
  Door Trim - Brass
  Fan Kit w/ variable speed control
  Outside Combustion Air Vent (closure & nonclosure)
  Ash Chute & Cover
  Outside Clean Out Door (for ash dump)
  Top Plate w/ Precut Ctr Hole/Straight Wall-Recessed Mantel
  10" Round Stack Pipe - Straight
  44" Lintel Iron
  5", 10" & 14 1/2" Offset Stacks
  10" Round Metal Chimney Adaptor for use with 10" HT, Class "A" Metal Chimney


   From Unit Sides to Face brick: 3/8"
  From Unit Top to Face Brick: 1/2"
  From Unit Back/Sides to Block Enclosure: 4"
  From Block Enclosure to Exterior Walls: 6"
   From Top of Grill Opening to Ceiling: 17"
   From Fuel Door to Combustion Mantel: 21"
  From Fuel Door to Side Wood Mantel: 10"
  From Side of Fuel Opening to Adjacent Wall: 24"
  From Top Slab to Wooden Header: 12"
  YOU MUST Cover Top Slab w/ 6" Non-Faced Fiberglass Insulation
  From Wooden Header to Chimney Block: 2"
  From 10" Stack Pipe to Bottom of Top Slab: 1"

 REQUIRED CHIMNEY TERMINATION
 10", HT, Class "A", 2100 , Insulated Double Wall Metal Chimney OR
 12" x 12" Clay Flue
 Minimum Height -10'
 30 Angle Maximum Offsets
 Minimum 5" Offset Required w/ Recessed Mantel
 OUTSIDE AIR TERMINATION
 6" Outside Air Flex Pipe for Chamber only - (included w/ unit) (connects intake air on fireplace to 6" - 30 ga. galv. pipe)
 Minimum Thickness - 30 Gauge Galvanized Pipe
 Elbows - Maximum - 3
 Do Not Terminate to Attic or Garage
 3' Clearance Below Chimney if Terminating Beside Chase
 Maximum Termination - 26'

  234 masonry manual
  234 masonry line drawing
  234 masonry brochure
  Tested by Warnock Hersey and complies with U.L. standard 127 (7/90) and CAN/ULC-S610-M87
   EPA exempt
   Air seal doors
   Ceramic glass
   Intake & exhaust air dampers
   

100% outside air for combustion